Rugged, water-resistant polycarbonate shell with protective concussion-proof overmold. RFI resistant.
Dimensions:
3.7 x 2 x 1.1 inches (94 mm x 50.8 mm x 27.9 mm)
Weight:
3 oz. (85 grams)
Measuring Ranges:
Gas
Symbol
Range
Increments
Carbon Monoxide
CO
0-1,500
1 ppm
Hydrogen Sulfide
H 2 S
0-500 ppm
0.1 ppm
Oxygen
O 2
0-30% of volume
0.1%
Nitrogen Dioxide
NO 2
0-150 ppm
0.1 ppm
Sulfur Dioxide
SO 2
0-150 ppm
0.1 ppm
Ammonia
NH 3
0-500 ppm
1 ppm
Chlorine
Cl 2
0-100 ppm
0.1 ppm
Chlorine Dioxide
ClO 2
0-1 ppm
0.01 ppm
Phosphine
PH 3
0-10 ppm
0.01 ppm
Hydrogen Cyanide
HCN
0-30 ppm
0.1 ppm
Hydrogen
H 2
0-2,000 ppm
1 ppm
CO/H2 low
CO/H2 low
0-1,000 ppm
1 ppm
Display:
Custom LCD with graphical icons for easy use
Segmented display for direct gas readings
Backlight for low light conditions
"Go/no-go" display mode
Peak reading indication
Alarms:
User selectable low and high alarms
Ultra-bright LEDs, loud audible alarm (95 dB) and vibrating alarm
Battery/Runtime:
User replaceable 3V, CR2 Lithium battery
2,600 hour runtime (typical)
Event-Logger:
Continually on. Logs last 15 alarm events, stamping how long ago the event occurred, the duration of the event, and the peak reading seen during the event.
Event-logger can be viewed on PC or printed directly from the instrument to an infrared printer.
Datalogger:
One year at one-minute intervals
Temperature Range:
-40ºC to 60ºC (-40ºF to 140ºF), typical
Humidity Range:
0-99% RH (non-condensing), typical
Approvals:
UL and cUL:
- Class I, Div 1, Groups A, B, C, D; T4
- Class I, Zone 0, AEx ia IIC T4
CSA:
- Class I, Div 1, Groups A, B, C, D; T4
- Ex ia IIC T4
ATEX:
-Intrinsic Safety:Safety: EEx ia I/IIC T4
-Equipment group and Category: II 1G; I M2
-EMC: EN50270
Performance: O 2 (EN50104); CO, H 2 S, (EN45544) (pending)
Australia: Ex ia I/IIC T4
IEC: Ex ia IIC T4
Russia: GOST-R Approval (pending)